Shrinkable sleeve is applied to the optical fiber closure to fix and protect the optical fiber when splicing.
The sleeve can be divided into two types (single sleeve and ribbon sleeve) according to the function.
The single type is used for the single-fiber, and the mass type is used for the ribbon fiber. It is different in the reinforcement between two types. The single one realizes the reinforcement by the stainless steel needles, the later one via the ceramic reinforcement member to realize the function.
Ribbon sleeve means there are several cores for the fiber. So the mass sleeve includes 4cores, 6cores, 8cores, 12 cores (for types).
Characteristics
Single holed (pre-shrunk)
Clear sleeve design
Smooth stainless steel reinforcing member
Sealing structure suitable to temperature
Extended liner length
Low shrink temperature
Pre installed stainless steel or ceramic rod
Accommodates single or ribbon fibers
Wide range of sizes
Operating temperature -45degree to 100degree
Min. full recovery temp: 120degree
Applications
Fusion splicing,
Fiber cable protecting
Specifications
Size Splice protector(mm) Fusion tube(mm) Steel rod(mm) Packing
O.D L I.D L O.D L (pcs/bag)
Large sleeves
TWSP-61 3 61 1.4 61 1.5 55 100
TWSP-45 3 45 1.4 45 1.5 40 100
TWSP-23 3 23 1.4 23 1.5 18 100
Standard sleeves
TWSP-61T 2.5 61 1.4 61 1 57 100
TWSP-45T 2.5 45 1.4 45 1 41 100
TWSP-40T 2.5 40 1.4 40 1 36 100
TWSP-30T 2.5 2.5 1.4 30 1 36 100
TWSP-25T 2.5 2.5 1.4 25 1 21 100
Mini/micro sleeves
TWSP-40M 1.3 40 0.35 40 0.5 40 100
TWSP-25M 1.3 25 0.35 25 0.5 25 100
TWSP-18M 1.3 18 0.35 18 0.5 18 100
TWSP-15M 1.3 15 0.35 15 0.5 15 100
TWSP-10M 1.3 10 0.35 10 0.5 10 100
Properties Test Method Typical Data
Tensile Strength(MPa) ASTM D2671 18
Ultimate Elongation (%) ASTM D2671 700
Density(g/cm3) ISO R1183D 0.94
Dielectric Strength(KV/mm) IEC 243 20
Dielectric Constant IEC 243 2.5
Longitudinal Change (%) ASTM D2671 5
Operating Temperature (℃) -55~+60
Shrinking Temperature Range (℃) +90~+110
Ordering Information
Illustration
The sleeve can be divided into two types (single sleeve and ribbon sleeve) according to the function.
The single type is used for the single-fiber, and the mass type is used for the ribbon fiber. It is different in the reinforcement between two types. The single one realizes the reinforcement by the stainless steel needles, the later one via the ceramic reinforcement member to realize the function.
Ribbon sleeve means there are several cores for the fiber. So the mass sleeve includes 4cores, 6cores, 8cores, 12 cores (for types).
Characteristics
Single holed (pre-shrunk)
Clear sleeve design
Smooth stainless steel reinforcing member
Sealing structure suitable to temperature
Extended liner length
Low shrink temperature
Pre installed stainless steel or ceramic rod
Accommodates single or ribbon fibers
Wide range of sizes
Operating temperature -45degree to 100degree
Min. full recovery temp: 120degree
Applications
Fusion splicing,
Fiber cable protecting
Specifications
Size Splice protector(mm) Fusion tube(mm) Steel rod(mm) Packing
O.D L I.D L O.D L (pcs/bag)
Large sleeves
TWSP-61 3 61 1.4 61 1.5 55 100
TWSP-45 3 45 1.4 45 1.5 40 100
TWSP-23 3 23 1.4 23 1.5 18 100
Standard sleeves
TWSP-61T 2.5 61 1.4 61 1 57 100
TWSP-45T 2.5 45 1.4 45 1 41 100
TWSP-40T 2.5 40 1.4 40 1 36 100
TWSP-30T 2.5 2.5 1.4 30 1 36 100
TWSP-25T 2.5 2.5 1.4 25 1 21 100
Mini/micro sleeves
TWSP-40M 1.3 40 0.35 40 0.5 40 100
TWSP-25M 1.3 25 0.35 25 0.5 25 100
TWSP-18M 1.3 18 0.35 18 0.5 18 100
TWSP-15M 1.3 15 0.35 15 0.5 15 100
TWSP-10M 1.3 10 0.35 10 0.5 10 100
Properties Test Method Typical Data
Tensile Strength(MPa) ASTM D2671 18
Ultimate Elongation (%) ASTM D2671 700
Density(g/cm3) ISO R1183D 0.94
Dielectric Strength(KV/mm) IEC 243 20
Dielectric Constant IEC 243 2.5
Longitudinal Change (%) ASTM D2671 5
Operating Temperature (℃) -55~+60
Shrinking Temperature Range (℃) +90~+110
Ordering Information